Providing you the best range of 4098-975 simplex-truealarm photoelectric and heat multi sensor detector, simplex manual call point, simplex-monitor zam module-4090-9101, addressable simplex (4099-9006) manual call point and simpex interface network card-4010-9922 with effective & timely delivery.

4098-975 SIMPLEX-TrueAlarm Photoelectric And Heat Multi Sensor Detector

Request Callback

₹ 2430 Get Latest Price

Product Brochure
Alarm Sensor TypePhotoelectric
Body MaterialABS Plastic
Startup Time (sec)20 sec
Operating Temperature15 TO 122 F
Brand/CompanySIMPLEX

Minimum order quantity: 1 Piece

TrueAlarm photoelectric smoke sensing and heat sensing combined in one housing to provide:  Smoke activity accurately monitored by TrueAlarm photoelectric sensing technology  Thermal activity accurately monitored by TrueAlarm thermistor sensing technology  And TrueSense detection, a correlation of smoke activity and thermal activity providing intelligent fire detection earlier than with either activity alone.<br />For use with Simplex&reg; 4007ES, 4010ES, 4100ES, and 4100U fire alarm control panels:  TrueAlarm analog sensor information is digitally communicated to the control panel via IDNet two-wire communications  Special point types allow the 4098-9754 multi-sensor to communicate smoke and heat analog sensing data using only one IDNet address  Individual sensor information is processed by the host control panel to determine sensor status and to determine whether conditions are normal, off-normal, or alarm  (4100U fire alarm control panels require software revision 11 or higher with multi-point compatible IDNet transmission modules)&nbsp;

Simplex Manual Call Point

Request Callback

₹ 2750 Get Latest Price

Product Brochure
MaterialMild Steel
Relay OutputsAlarm Relay, Trouble Relay, Supervisory Relay
Usage/ApplicationIndustrial
Working Voltage12 to 32 v DC
ColorRed
Control KeysSystem Reset, Mute Buzzer, Evacuate
Audible AlarmYes
Fire ResistanceYes
Country of OriginMade in India

Minimum order quantity: 1 Piece

Simplex addressable manual pull stations allow occupants to signal a fire or other emergency condition. An integrated LED confirms both connection with the control unit and alarm activation.

SIMPLEX-Monitor ZAM Module-4090-9101

Request Callback

₹ 3550 Get Latest Price

Product Brochure
Power Supply24 VDC
BrandSimplex
Model Name/Number4090-9101

Minimum order quantity: 10 Piece

  • Mechanically Installing the Monitor ZAM Install the Monitor ZAM into a grounded 4-inch UL Listed back box (not supplied) using Figure 4: Monitor ZAM Back Box Installation on page 4 as a reference. Mount the ZAM to the back box as follows: 
  • Loosen the two screws on the square back box. 
  • Mount the ZAM to the back box using the teardrop holes on the mounting bracket. 
  • Secure the ZAM to the back box using the two #8/32 panhead screws.
  • Setting the Monitor ZAM's address NOTE: The IDNet channel supports address codes 1 through 250. The MAPNET II channel (4100, or 4120, or 4020 FACP) supports address codes 1 through 127. Each Monitor ZAM has a unique address. The address of the ZAM is set via an eight-position DIP switch. See Figure 1: Monitor ZAM installation on page 1. DIP switch position 1 is the least significant bit (LSB) and position 8 is the most significant bit (MSB). Set the ZAM's address using Figure 2: Monitor ZAM address chart on page 2 as reference. Use a small screwdriver or pen to set the switches. 
  • Making electrical connections to the Monitor ZAM Input and output signals connect to the Monitor ZAM via the terminals (1-8) as illustrated in Figure 1: Monitor ZAM installation on page 1. Terminal connections for the ZAM are illustrated in Figure 3: Monitor ZAM connections for Class A ZAM 4090-9106, 2-wire Class B ZAM 4090-9101, and 4-wire Class B ZAM 4090-9101 on page 
  • When connecting two wires to one terminal, position one wire on each side of the terminal screw. 2. IDNet and MAPNET II lines are 18 AWG twisted pair (shield recommended). 3. Maximum allowable run from FACP to farthest device not to exceed 2500 feet. 4. Power must be provided from FACP, 4009, or regulated Power-Limited 24VDC supply that is listed for Fire-Protective signaling use, except for some detectors which require the 4100-5130 voltage regulator. Refer to 579-832 Two-Wire Detector Compatibility chart for the model numbers for those detectors. 5. Refer to Field Wiring Diagram 842-073 for further information on wiring Monitor ZAMs to IDNet. Refer to Field Wiring Diagrams 841-804 or 841-996 for further information on wiring Monitor ZAMs to MAPNET II. IDNet and MAPNET II wiring are supervised and power-limited.

Addressable Simplex (4099-9006) Manual Call Point

Request Callback

₹ 2550 Get Latest Price

Product Brochure
Model Name/NumberSimplex (4099-9006)
TypeAddressable
System ComponentsManual Call Point
ColorRed
The 4099-9006 Simplex Addressable Manual Call Point Combines The Familiar Simplex Manual Station Housing With a Compact Communication Module That is Easily installed to Satisfy Demanding Applications.

Simpex Interface network card-4010-9922

Request Callback

₹ 30500 Get Latest Price

Product Brochure
Automation GradeFully Automatic
Usage/ApplicationIndustrial
BrandSimplex
System ComponentsFire Alarm Control Panel

Minimum order quantity: 5 Piece

Interconnect Simplex® Fire Alarm Network nodes using facility Ethernet LAN (Local Area Network) communications:  Converts fire alarm Network communications into Transmission Control Protocol (TCP) using Internet Protocol (IP) formatting to connect between destination and source IP addresses  Network communications from any node to any other node can pass through up to two (2) TCP/IP links  Network topologies include ring (loop), star (hub), interconnection of Network loops, and combinations  Hub Nodes act as data proxies allowing multiple Hub Nodes with Remote Nodes per Network loop (refer to page 3 for additional details)  Class X (Style 7) pathway connections from Hub Nodes to Remote Nodes are compatible with redundant LANs for increased communications integrity